A. The following sections of the International Plumbing Code, 2018 Edition, are amended to read as follows:

1. Section 101.1 Title is amended by adding the name "Town of Breckenridge".

2. Section 101.3 Intent is amended to add the following sentences:

The intent of this code is to meet or exceed the requirements of the State of Colorado Plumbing Code. When technical requirements, specifications or standards in the Colorado Plumbing Code conflict with this code, the more restrictive shall apply.

3. Section 103.2 Appointment is amended to read exactly as set forth in IBC Section 103.2 as amended.

4. Section 103.3 Deputies is amended to read exactly as set forth in IBC Section 103.3 as amended.

5. Section 103.4 Liability is amended by adding the first paragraph as written in IBC Section 104.8 as amended.

6. Section 106.5.3 Expiration is amended to read exactly as set forth in IBC Section 105.5 as amended.

7. Section 106.5.4 Extensions is deleted in its entirety.

8. Section 106.6.2 Fee schedule is amended to read as follows:

106.6.2 Fee schedule. The fees for plumbing work shall be in accordance with the Town of Breckenridge Building Permit and Inspection Fee Schedule as set forth in IBC Section 109.2 as amended.

9. Section 106.6.3 Fee refunds is amended to read as follows:

106.6.3 Fee refunds. The building official is authorized to establish a refund policy.

10. Section 107.2 Inspections and Testing is amended by adding a new subsection, 107.2.6 Re-inspections, to read as follows:

107.2.6 Re-inspections is to read exactly as set forth in IBC Section 110.7 as amended.

11. Section 108.4 Violation penalties is amended to read exactly as set forth in IBC Section 114.4.

12. Section 108.5 Stop work orders is amended to read exactly as set forth in IBC Section 115.

13. Section 109 Means of appeal is deleted in its entirety and reenacted to read exactly as set forth in IBC Section 113.

14. Section 301 General is amended by adding a new subsection, 301.8 Floor drains, to read as follows:

301.8 Floor Drains. All mechanical, furnace, boiler and water heater rooms shall be provided with a floor drain.

15. Section 305.4.1 Sewer depth is amended to read as follows:

305.4.1 Sewer depth. Building sewers shall be installed in accordance with the standards and approval of the governing Sanitation District.

16. Section 312.3 Drainage and Vent Air Test is amended by deleting the first sentence; "Plastic pipe shall not be tested using air."

17. Section 312.5 Water supply system test is amended by deleting the portion of the sentence reading "for piping systems other than plastic."

18. Section 312.6 Gravity sewer test is amended to read as follows:

312.6 Gravity sewer test. Testing of the building sewer shall be in accordance with the standards and approval of the governing Sanitation District.

19. Section 312.7 Forced sewer test is amended to read as follows:

312.7 Forced sewer test. Testing of the building sewer shall be in accordance with the standards and approval of the governing Sanitation District.

20. Section 312.9 Shower liner test is deleted in its entirety.

21. Section 403.1 Minimum number of fixtures is amended to read exactly as IBC Section 2902.1 as amended.

22. Section 403.2 Separate facilities Exception 2 is amended by changing the total occupant load from 15 to 30.

23. Section 403.2 Separate facilities is amended by adding an Exception 5 to read as follows:

Exception 5. Gender neutral single-user toilet facility and bathing room fixtures.

24. Section 403.2.1 Family or assisted-use toilet facilities serving as separate facilities is amended to read exactly as IBC Section 2902.1.2 as amended.

25. Section 504.6 Requirements for discharge piping Item 5 is amended by deleting the portion of the sentence "to the outdoors."

26. Section 504.7.2 Pan drain termination is amended to read as follows:

504.7.2 Pan drain termination. The pan drain shall extend full-size and terminate over a suitably located indirect waste receptor or floor drain.

27. Section 608.18.1 Well locations through Section 608.18.8 Drainage are deleted in their entirety.

28. Section 610.1 General is amended to read as follows:

610.1 General. New or repaired potable water systems shall be purged of deleterious matter and disinfected prior to utilization. The method to be followed shall be that prescribed by the Town of Breckenridge Water Department.

29. Section 701.2 Connection to sewer required is amended to read as follows:

701.2 Connection to sewer required. Every building in which plumbing fixtures are installed and all premises having drainage piping shall be connected to a public sewer.

30. Section 903.1 Roof extension is amended to read as follows:

903.1 Roof extension. All open vent pipes which extend through a roof shall terminate at least 12 inches above the roof and within 5 feet of a ridgeline.

31. Section 1106.1 General is amended to read as follows:

1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers, and any horizontal branches of such drains or sewers shall be based on the 100-year hourly rainfall rate of two inches per hour.

32. Section 1109.1 General is amended to read as follows:

1109.1 General. Combination sanitary and storm drains or sewers are prohibited.

(Ord. 38, Series 2019)